New Crystal Photodiode Combination for Environmental Radiation Measurement

Authors

DOI:

https://doi.org/10.61326/jaasci.v2i2.103

Keywords:

Environmental radiation , Radiation measurement, Scintillation crystals, ZnS–Si photodiodes

Abstract

Here, a new design will be introduced to detect radiation in the environment with high efficiency. The designed structure consists of placing ZnS–Si APD and PIN photodiodes at the ends of conventional crystals such as NaI(Tl) and CsI(Tl). Since ZnS is transparent to photons with wavelengths between 340 and 10000 nm, photons coming from the crystals are absorbed directly in the depletion region and generate primary particles. With an increase in the number of generated primary particles, a stronger and cleaner signal is obtained. In the simulation work, the light generated by 30 keV–3 MeV gamma rays in the crystals was obtained using the Geant4 simulation code. The single-particle Monte Carlo technique was used to calculate the photodiode output signal for the crystal emission spectrum. The simulation results showed that the crystals and ZnS–Si photodiode structures formed a good combination. The high quantum efficiency and low excess noise factor make the ZnS–Si structure an excellent choice for scintillating light detection.

References

Koyama, S., Miyamoto, Y., Fujiwara, A., Kobayashi, H., Ajisawa, K., Komori, H., Takei, Y., Nanto, H., Kurobori, T., Kakimoto, H., Sakakura, M., Shimotsuma, Y., Miura, K., Hirao, K., & Yamamoto, T. (2010). Environmental radiation monitoring utilizing solid state dosimeters. Sensors and Materials, 22(7), 377-385.

Lowder, W. M., & Condon, W. J. (1965). Measurement of the exposure of human populations to environmental radiation. Nature, 206(4985), 658-662.

Lowdon, M., Martin, P. G., Hubbard, M. W. J., Taggart, M. P., Connor, D. T., Verbelen, Y., Sellin, P. J., & Scott, T. B. (2019). Evaluation of scintillator detection materials for application within airborne environmental radiation monitoring. Sensors, 19(18), 3828-3841. https://doi.org/10.3390/s19183828

Sáez-Vergara, J. C. (2000). Recent developments of passive and active detectors used in the monitoring of external environmental radiation. Radiation Protection Dosimetry, 92(1), 83-88. https://doi.org/10.1093/oxfordjournals.rpd.a033289

Tapan, I., Ahmetoglu, M. A., & Kocak, F. (2006). A ZnS–Si isotype heterojunction avalanche photodiode structure for scintillation light detection. Nuclear Instruments and Methods in Physics Research A: Accelerators, Spectrometers, Detectors and Associated Equipment, 567(1), 268-271. https://doi.org/10.1016/j.nima.2006.05.105

The Geant4. (2023). The Geant4 simulation code. Geant4 A Simulation Toolkit. https://geant4.web.cern.ch/

The Hamamatsu Photonics. (2023). Radiation sensors. Hamamatsu. https://www.hamamatsu.com/eu/en/product/optical-sensors/radiation-sensor.html

Zhang, J., Xiang, Y., Wang, C., Chen, Y., Tjin, S. C., & Wei, L. (2022). Recent advances in optical fiber enabled radiation sensors. Sensors, 22(3), 1126-1149. https://doi.org/10.3390/s22031126

Downloads

Published

18-12-2023

Issue

Section

Research Articles